CGO-4-N Open-loop Cryogenic Vacuum Probe Station


High vacuum chamber with 77K-473K (upgradeable to 573K, 773K) temperature range.

Non-destructive electrical analysis for materials and front-end devices

Applied to DC, RF/mmW testing; as well as MEMS and optoelectronic testing, among others.

Provide effective cryogenic operation, using liquid nitrogen or liquid helium for continuous cooling of the system.

No water and frost formation at low temperatures to ensure that the sample is dry.

Affordable - competitive price in it's class.

Intergrated air floting vibration isolation design, smaller space occupation, to provide a good experimental environment for the laboratory.

Category:

CGO Series Vacuum High- and Low-Temperature Probe Station

  • Description
  • Parameters
  • Download
  • Video
  •  

    Features:

     

    High vacuum chamber with 77K-473K (upgradeable to 573K, 773K) temperature range.

    Provide effective cryogenic operationusing liquid nitrogen or liquid helium for continuous cooling of the system.

    No water and frost formation at low temperatures to ensure that the sample is dry.

    Affordable - competitive price in its class.

    One-piece vibration isolation design, smaller space occupation, to provide a good experimental environment for the laboratory.

     

    Descriptive

     

    (1)Cindbest's CGO-4-N provides cryogenic environments with vacuum levels of 10^-3pa or 10^-6 mbar. Meets requirements for non-destructive measurements of electrical properties of materials and early stage electronics

    (2)Users can start with a standard system and upgrade to a higher level probe station with higher vacuum and temperature ranges. Specialized designs are also available upon request.

    (3)Typical applications include sampling IV and CV curves over a wide temperature range, measuring microwave and electro-optical responses, characterizing magnetic transport properties in variable magnetic fields, Hall effect measurements to understand carrier mobility, and a variety of other materials studies

     

    Composition of the whole machine

    Table body module, probe arm moduleoptical microscope systemtemperature control systemvacuum systemcryogenic system, magnetic field (optional)

     

     

     

     

    Description

     

    • 8-inch vacuum chamber with high infrared transmittance and high visible light transmission observation window (optional recessed window)  
    • Sample stage size: 4 inches, electrically isolated and suspended  
    • 6 probe arm interfaces (compatible with DC, fiber optic, and RF arms)  
    • One KF40 vacuum port with needle valve control switch, one quick vacuum release inlet  
    • One 20-pin aviation connector, allowing for quick installation and removal  
    • Coaxial refrigerant inlet for improved coolant efficiency  
    • KF flange interface, system ultimate vacuum better than 10^-5 Torr  
    • Leak rate: better than 1*10^-10 Pa·m³/s  
    • Cooling time from room temperature to 80K: better than 30 minutes  
    • Temperature range: 78K to 473K  
    • Integrated vibration damping stand (optional air-bearing anti-vibration stand)  
    Size: 760 * 730 * 1220mm
    Weight: 85KG

     

    Install requirements

    Single-phase power: 220V, 50Hz

    No water requirement

    The air Floatation bracket needs to be equipped with an air line to inflate it, or the option to add accessories (air compressor)

    Space reservation: 3M*1.5M

    Avoid placing equipment that generates high vibration in the same space.

  •  

    FEATURES

     

    2 to 4 inch sample stations available

    Compact desktop design 

    Rapid cooling and warming 

    Compatible with IV/CV/DC/RF,ETC testing

    Temperature range 77K-473K

    Integratable photocurrent test

    Can be matched with electromagnetic field for high and low temperature Hall test

     

     

     

    Table Body Module

     --Key technical parameters

    Temperature range

    77K~473K

    Sample table size

    4 inches, sample stage electrically independent suspension

    Sample table material

    Gold-plated copper

    Vacuum Cavity Size

    8 inches.

    Cavity Material

    stainless steels

    Viewing window

    2-inch high visible light transmission viewing window (optional sunken window)

    Cooling rate

    Cooling time from room temperature to 80K is better than 30mins.

    Vacuum

    System ultimate vacuum better than 10^-5 Torr

    Leakage accuracy

    Leakage accuracy better than 100fA (upgradeable to 30fA)

    Magnetic fields

    Optional horizontal magnetic field, ±0.6T@100mm

    Probe Arm Interface

    6 probe arm interfaces (compatible with DC arm, fiber optic arm, RF arm)

    Other interfaces

    One KF40 vacuum extraction port with needle valve control switch, one quick break vacuum inlet port

    Other interfaces

    One 20-pin aviation plug for quick installation and removal

    Other interfaces

    Coaxial refrigerant inlet for improved refrigerant efficiency

    Brackets

    One-piece vibration isolation mount (optional air-bearing anti-vibration mount)

    Sizes

    Size: 760*730*1220

    Weights

    Weight: 85KG

    Probe arm 

    DC Arm CB-80-N

    RF Arm CB-80-RF

    Fiber optic arm CB-80-F

     

    DC arm

    Suitable for loading DC probes

    Radio-frequency arm

    Suitable for mounting RF probes (with R-axis rotation function to help RF probes level quickly)

    Fiber optic arm

    Suitable for loading optical fiber into the chamber for irradiating samples

    Probe arm X-Y-Z travel range

    25mm-70mm-15mm

    R-axis rotation angle

    Coarse adjustment 360 degrees, fine adjustment ±7.5 (unique to RF arm)

    Movement accuracy

    ±2um

     

     

    Probe Fixture

      DC Fixture

    Kelvin Fixture

    RF Probe Fixture

    High Voltage

     Probe Fixture

    High Current Probe Fixture

    Fiber Optic Fixture

     

    Maximum voltage

    250V

    50V

    3KV/10KV

    1KV

    Fiber Retention Fixture

    Maximum current

    1A

    2A

    5A

    100A/200A

    leakage current

    < 10fA

    100fA

    300fA@ 3 kV

    /

    terminal (electrical engineering)

    SSMC Female

    2.92/2.4/1.85/1.0mm

    Triple coaxial/BNC/banana head

    banana head

    Matching probe type

    Kelvin Replacement Probes

    40/50/60/110 GHz probes

    Coarse Tip DC Probes

    Multi-Finger Probe

    Probe Tip Material

    molybdenum

    Beryllium Copper/Nickel Plated/Tungsten

    molybdenum

    copper (chemistry)

    Probe tip Radius

    0.5-20um

    20um

    20/50/100um

    /

    Appliance

    Low leakage test

    High Frequency Testing

    High Voltage Pulse Test

    High Current Pulse Test

     

    Kelvin probe fixation

     

     

     

     

    RF Probe Fixation

     

    High current probe fixation

    High current probe fixation

     

     

    vTemperature control system  

     

    Temperature range

    77K-473K

    Temperature control accuracy

    0.1°C (scalable)

    Temperature stability

    ±0.1°C @300K-473K

    Heating method

    Heating wire (resistance heating)

    Cooling method

    Liquid Nitrogen/Liquid Helium

    Temperature control

    Manual control valves

    Cooldown

    Reduced to 80K within about 30 min (liquid nitrogen refrigeration)

    Heating time

    Reaches 473K within about 30min (room temperature to 473K)

    Temperature sensor

    1 mounted on sample stage

    magnetic field

    Magnetic field strength

    >Staff 0.6T@20mm

    Input power

    3500W

    Coil resistance

    DC resistance @20°C:0.68Q

    Cooling method

    water cooling

     

     